Elcometer 500 Coating Thickness Gauge – Cementitious Substrates

Fast and accurate, the Elcometer 500 Coating Thickness Gauge takes repeatable and reproducible dry film thickness measurements of coatings on concrete up to 10mm thick – without damaging the coating.

Taking over 60 readings per minute in standard mode and 140+ readings per minute in scan mode; the Elcometer 500 Coating Thickness Gauge allows users to inspect more coatings in less time. With a choice of intelligent, ergonomic probes, designed for continuous use and field replaceable probe tips you can inspect all day, everyday.

The built in signal strength indicator on the Elcometer 500 Coatings on Concrete Gauge prevents false or incorrect readings, as the gauge only displays the coating thickness measurement if the signal strength indicator goes green.

Robust, ergonomic and sealed against dirt and water, equivalent to a rating of IP54, the Elcometer 500 Concrete Coating Thickness Gauge has been designed to work in harsh environments.

Incredibly easy to use, the Elcometer 500 Coating Thickness Gauge for concrete can be used in accordance with ASTM D6132, SSPC PA9 & ISO 2808 Method 10.

Compatible with ElcoMaster® software and ElcoMaster® Mobile App, individual coating thickness measurements can be transferred via USB or Bluetooth® to PC or a mobile device for analysis and instant report generation.

Description

Fast

Measuring over 60 readings per minute in standard mode and over 140 readings per minute in scan mode, the Elcometer 500 Coating Thickness Gauge can significantly reduce your inspection times.

Intelligent

The Elcometer 500 Coatings on Concrete Gauge measurement probes are supplied with user replaceable probe tips. If the tip is damaged or wears during use you can replace it and carry on.

The gauge even informs you when you need to change the probe tip, maximising inspection time.

Reliable

The Elcometer 500 Coating Thickness Gauge will only display the coating thickness reading if the signal strength indicator turns green, preventing false or incorrect readings.

If the coating thickness is outside the measurement range, the Elcometer 500 Concrete Coating Thickness Gauge tells you on the display.

Easy to Use

There is no need to set up gates, range values or know the thickness of the coating, simply select the coating material from the gauge library and start measuring.

Ergonomic

The Elcometer 500 Coatings on Concrete Thickness Gauge and intelligent probes have all been ergonomically designed for continuous use. No force is required to take a reading.

Rugged

Robust, ergonomic and sealed against dirt and water, equivalent to a rating of IP54, the Elcometer 500 Coating Thickness Gauge has been designed to work in harsh environments, making it the ideal gauge for the laboratory or the job site.

Elcometer 500 Coating Thickness Gauge Model B

The Elcometer 500 Model B Coating Thickness Gauge accurately measures the thickness of coatings on concrete and other similar substrates – non destructively. Taking over 60 readings per minute.

  • Model: Model B
  • Probe Option: Supplied Separately
  • Part Number : A500C-B
  • Certification : Test Certificate
Elcometer 500 Coating Thickness Gauge Model T

The Elcometer 500 Model T Coating Thickness Gauge accurately measures the thickness of coatings on concrete and other similar substrates – non destructively. Taking over 60 readings per minute in standard mode and 140+ readings per minute in scan mode.

  • Model: Model T
  • Probe Option: Supplied Separately
  • Part Number : A500C-T
  • Certification : Test Certificate
Elcometer 500 Coatings on Concrete Inspection Kit

Housed in a sturdy, protective carry case and containing all the equipment required for on-site inspection of coatings on concrete and other similar substrates.

  • Part Number : A500-KIT1
  • Certification : Test Certificate
Elcometer 500 Scale C1 Probe

Accurately measure between 150 – 2,500μm (6 – 98mils) of coatings on concrete or other similar substrates.

  • Part Number : T500-C1
  • Certification : Test Certificate
Elcometer 500 Scale C2 Probe

Accurately measure between 750 – 9,000μm (30 – 355mils) of coatings on concrete or other similar substrates.

  • Part Number : T500-C2
  • Certification : Test Certificate
Part NumberDescriptionCertificate
A500C-BElcometer 500 Coating Thickness Gauge Model B
       Test Certificate supplied as standard
A500C-TElcometer 500 Coating Thickness Gauge Model T
       Test Certificate supplied as standard
A500-KIT1Elcometer 500 Coatings on Concrete Inspection Kit
       Test Certificate supplied as standard
Operating Temperature-10 to 50°C (14 to 122°F)
Power Supply2 x AA batteries (rechargeable batteries can be used)
Battery LifeAlkaline: Approx. 15 hours Lithium: Approx. 28 hours
Gauge Dimensions (h x w x d)141 x 73 x 37mm (5.55 x 2.87 x 1.46”) without transducer
Gauge Weight161g (5.68oz) including batteries, without transducer
Packing ListElcometer 500 Coating Thickness Gauge Model B / Model T
Elcometer 500 Coating Thickness Gauge, 4ml (0.14fl oz) bottle of probe tip oil, 120ml (4fl oz) bottle of ultrasonic couplant, 2 x AA batteries, protective case, transit case (Model T), wrist harness, 3 x screen protectors, ElcoMaster® software (Model T), USB cable (Model T), test certificate
Elcometer 500 Coatings on Concrete Inspection Kit
Elcometer 500 Model T Coating Thickness Gauge, C1 & C2 coating thickness probes, C1 & C2 probe measurement foils: 1, 2, 3 & 8mm (40, 80, 120 & 310mils), Elcometer 456 Model B Ferrous Integral Gauge, Elcometer 456 calibration foils: 0.5 & 1.5mm (20 & 60mils), 2 x coating calibration moulds, 120ml (4fl oz) bottle of ultrasonic couplant, 4ml (0.14fl oz) bottle of probe tip oil, transit case, ElcoMaster® software & USB cable

 

Probe Range
Scale C1
T500-C1Elcometer 500 Scale C1 ProbeTest Certificate supplied as standard
Range1150 – 2,500μm (6 – 98mils)
Accuracy2±2% or ±10μm (±2% or ±0.4mil)
ResolutionLow: 10μm, 0.01mm, 1mil or 0.001”
High: 1μm, 0.001mm, 0.1mil or 0.0001”
Scale C2
T500-C2Elcometer 500 Scale C2 ProbeTest Certificate supplied as standard
Range1750 – 9,000μm (30 – 355mils)
Accuracy2±2% or ±10μm (±2% or ±0.4mil)
ResolutionLow: 10μm, 0.01mm, 1mil or 0.001”
High: 1μm, 0.001mm, 0.1mil or 0.0001”